Flow, level, and temperature instrument innovators since 1964
   

AS-TS Temperature Switch

 
Download literature
for this product

Summary

FCI provides temperature switches mounted in thermowells with integral or remote solid state electronics housed in protective enclosures for direct installation into piping and ducting on commercial and military aircraft, spacecraft, vehicles and marine applications. These switches utilize highly reliable Resistance Temperature Detector (RTD) elements that provide a linear change in resistance that is directly proportional to temperature changes in the liquid or gas process. The FCI provided electronics are equipped with up to three separate switch points that are set by FCI at customer specified values to indicate temperature changes in the customer’s process fluid. FCI can also provide thermistor and thermocouple elements with switch electronics for requirements specified by the customer.

Please complete and submit the attached Application Data Sheet or contact FCI’s Field Representative in your area to receive a technical quotation for your Temperature Measurement Switch application.
 

Applications

 
Environmental cooling systems Cabin air temperature management
Power management systems Temperature limit alarms
Fluid temperature control Other fluids and gases

Specifications

Service: Liquid or gas temperature
Accuracy: ± 2° F [± 1° C]
Repeatability: ± 1° F [± 0.5° C]
Reliability (MTBF): 100,000+ Hours.
Qualifications: MIL-STD-130 Marking, MIL-STD-810 Environmental Testing, MIL-STD-889 Dissimilar Metals and MIL-STD-461/462 EMI.
Quality System Approvals: ISO9001 and AS9000
Weight: 0.23 lbs. [0.10 kgs]

Temperature Element

Materials of Construction:
Standard: All welded 300 series stainless steel.
Optional: Aluminum, titanium or other alloys available with hermetically sealed connectors.
Process Connection: Flanged or threaded per AS930, AS4395, MS33656.
Insertion Length: 0.160 to 4 inches [4 to 101 mm].
Operating Temperature: -40° to +212° F [-40° to +100° C] (wider temperature range optionally available).
Operating Pressure: To 7500 psig [517 bar(g)].
Proof Pressure: To 12,500 psig [861 bar(g)].
Enclosure: Environmental seal; Hermetically sealed option.
Electrical Connection: Military, commercial connector; pigtail cable of customer specified type and length.
Electrical Parameters
Input Current: < 10 mA.
I.R. Test Voltage: < 500 Vdc.
D.R. Test Voltage: < 500 Vdc.
Bonding: < 2.5 milliohms.
Environmental Parameters
Altitude: 100,000 ft. [30,480 m]
Humidity: 100%.
Thermal Shock: 10° C per minute.
Vibration: Rotary, Fixed Wing
Acceleration: 10 gs.

Optional N.I.S.T. Test Lab Calibration Services
Factory N.I.S.T. calibration is available as an option for customer specified setpoint(s).

 



Home | About FCI | Products | Applications | Sales  | News/Events | Support | Contact FCI | Search | Site Map
©2010 Fluid Components International LLC. All Rights Reserved   Contact Us at 800-854-1993 or 760-744-6950
Legal & Privacy Statements