FR73B BASIC Low Flow FlexSwitch®

Flow Switch FR73B


Download literature
for this product

Flow Switch Summary

The FR73B BASIC inline type low flow switch provides a very precise linear output signal for extremely low gas and liquid flows in either direction. With detection capability from 1 to 1000 cc/min in gas and 0.01 to 2 cc/min in liquids, this instrument is an ideal switching device for test and measurement applications such as gas chromatography and fluid sampling systems.

This instrument produces a millivolt output signal that is positively correlated with the flow rate.  The signal is suitable for computer input and can be read using FCI's Model FM71D Monitor/Calibrator or customer supplied voltmeter.

The FR73B BASIC responds in as little as 1 second depending upon the type of media and flow velocity. With 0.125 inch 316 stainless steel tubing and an inlet to outlet volume less than 0.8 cc, the unit is quickly and easily purged to prevent sample contamination in test applications.
 

Applications

Sample flow and gas chromatography
Leak detection

 

Specifications

Setpoint Range:
Water-based Liquids:
0.01 to 1.25 cc/min
Hydrocarbon-based Liquids:
 0.04 to 2 cc/min
Air/Gas:
1 to 1000 cc/min
Repeatability: 1% of full signal range at constant process conditions
Response Time: As low as 1 second
Enclosure:
Standard: No circuit board enclosure
Optional: Epoxy coated feralloy rated for NEMA Type 4X and hazardous locations Groups B, C, D, E, F and G; CENELEC EEx d IIC and CE Mark (meets IP66)
Agency Approvals: Contact FCI.
 

Flow Element

Materials of Construction: All wetted surfaces 316 stainless steel with nickel braze per process specification AMS 4777
Process Connections: 0.125 inch tubing, 2 inches [50 mm] length with 0.028 inch [0.7 mm] wall thickness
Inline Length: 7 ± 0.25 inches [178 ± 6 mm]
Operating Temperature: -100° to +350° F [-73° to +177° C]
Operating Pressure: To 1000 psig [69 bar(g)]
Interconnecting Cable: 10 feet [3 m] Teflon
 

Control Circuit

Operation Temperature: -40° to +140° F [-40° to +60° C]
Input Power: 115 ± 15 Vac or 230 ± 30 Vac, 50/60 Hz, 22 to 30 Vdc; 6 watts maximum
Relay Contacts: SPDT rated 2 amps at 115 Vac and 24 Vdc or 1 amp at 230 Vac, plus millivolt output ± 500 mV 10 megaohm minimum input impedance
Dimensions: 3.6 inches [92 mm] diameter, 2.4 inches [61 mm] height
 


Home | About FCI | Products | Applications | Sales  | News/Events | Support | Contact FCI | Search | Site Map
©2008 Fluid Components International LLC. All Rights Reserved   Contact Us at 800-854-1993    Legal & Privacy Statements