Flow, level, and temperature instrument innovators since 1964
   

FS2000 NuTec® 2 Wire Thermal Flow Switch

Flow Switch NuTec FS2000


Download literature
for this product

Flow Switch Summary

The FS2000 insertion type NuTec represents the first thermal flow switch designed with 2 wire, 4 to
20 mA loop power. Using 24 Vdc input power, this design allows for retrofitting existing 2 wire failure prone mechanical float and paddle switches without wiring modifications. An alarm with SPDT relay and input power of 85 to 265 Vac, 24 Vdc or 24 Vac is available as an option. FCI is the only thermal manufacturer providing temperature compensation to ensure set point accuracy for process temperatures that vary up to ± 100° F.

All Nutec Series flow and level switches are designed with proven thermal mass flow sensor technology in a rugged package that is easy to install and requires minimal maintenance.
 

Applications

Pump protection Chemical injection
Seal leak detection HVAC monitoring
Lubricant monitoring Drain line flow

 

Specifications

Setpoint Range:
Water:
    0.01 to 1.5 fps  [0.03 to 0.45 mps]
Hydrocarbon-based Liquids:
    0.1 to 2 fps  [0.03 to 0.6 mps]
Air/Gas:
    0.5 to 100 sfps  [0.15 to 30 smps] at
    standard conditions of 70° F  [21.1° C] and 14.7 psia [1.013 bar(g)].
Repeatability: ± 1% of setpoint range
Response Time: 0.5 to 2.5 seconds
Enclosure: 
For 2-wire: Aluminum rated for hazardous location use (Class I and II, Division 1 and 2, Group C and D and resists the effect of weather and corrosion (NEMA/CSA Type 4X and equivalent to IP66).
For Alarm Relay: Aluminum rated for hazardous location use (Class I and II, Division 1 and 2, Group B, C, D, E, F and G; and EEx d IIC) and resists the effect of weather and corrosion (NEMA/CSA Type 4X and equivalent to IP66).
Agency Approvals:  FM, CSA, CRN, ATEX (pending) and CE Mark.

Flow Element

Materials of Construction: 304/305 stainless steel or 316L all welded stainless steel for all wetted surfaces.
Process Connection:
For 304/305 stainless steel: 0.25 inch male NPT.
For 316L stainless steel: 0.75 inch male NPT
Insertion Length:
For 304/305 stainless steel:
    0.60 inches  [15 mm]
    0.98 inches  [25 mm]
    2.23 inches  [57 mm]
    3.80 inches  [152 mm]
For 316L stainless steel: 0.75 inch male NPT
    2 inches  [51 mm]
    6 inches  [152 mm]
Customer specified lengths are available as an option.
Operating Temperature: -40° to +250° F  [-40° to +121° C]
Operating Pressure: To 500 psig  [35 bar(g)]


Control Circuit

Operating Temperature: 0° to +140° F  [-18° to +60° C]
Input Power:
For 2-wire: 22.5 to 30 Vdc, loop powered, 0.5 watt.
For Alarm Relay: 85 to 265 Vac at 3 watts, 24 Vac ± 2.5 Vac at 2.5 watts, or 24 Vdc +2.5/-1.5 Vdc at 2.5 watts.
Signal Output:
For 2-wire: 2 stepped outputs with alarm conditions at 14 mA ± 0.5 mA or 18 mA ± 0.5 mA field selectable.  NPN, open collector transistor 250 mA maximum current (alarm).
For Alarm Relay: 1 SPDT rated at 6 amps at 115 Vac, 240 Vac or 24 Vdc.
Electrical Connection:
For 304/305 stainless steel: 0.5 inch female NPT.
For 316L stainless steel: 0.75 inch female NPT

Optional N.I.S.T. Flow Calibration Services

Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above