MT86 Multipoint Air and Gas Mass Flow Meter for Large Line Sizes and Stacks
Mass Flow Meter SummaryThe MT86 insertion type multipoint mass
flow meter combines FCI's highly reliable thermal dispersion,
no-moving parts flow element design with up to 16 flow sensing
points while operating over a wide temperature range up to 850° F
[454° C]. The electronics features continuous built-in testing and
calibration adjustment to prevent signal drift.
The MT86 multipoint mass flow meter is ideal for installation in air
ducts, stacks, or wherever irregular flow profiles reduce the
effectiveness of single-point metering.
Applications |
|
|
Stack
monitoring for CEMS |
|
Flue gas
recirculation monitoring |
 |
Primary air
flow monitoring |
|
Scrubber
and precipitator balancing |
|
Combustion
air flow monitoring |
|
Air
monitoring to low NOX burners |
SpecificationsFlow Range: 0.25 to 150 sfps
[0.08 to 46 nmps] in
Air at standard conditions of 70° F [21.1° C] and 14.7 psia
[1.01325 bar (a)].
Accuracy: (at calibrated conditions) ± 2% of reading, ± 0.5% of full scale
Temperature Coefficient:
With optional temperature compensation. Valid from 10% to 100% of full-scale calibration
Flow: Maximum ± 0.015% of reading/ºF up to 850ºF [±0.03% of reading/ºC up to 454 ºC]
Repeatability: ± 1% reading
Turndown Ratio: From 5:1 to 100:1 within the
calibrated flow range.
Temperature Compensation:
Standard: ± 30° F [± -1° C]
Optional: ± 100° F [± 38° C]
Enclosure: Powder coated aluminum enclosure is rated
for NEMA/CSA Type 4 (equivalent to IP66).
An optional enclosure for hazardous locations is available.
Agency Approvals: Contact FCI.
N.I.S.T. Certified Test Lab Calibration: Standard
Flow ElementMaterials of Construction:
Standard: 316 stainless steel with nickel braze per
specification AMS 4777 for all wetted surfaces.
Optional: Hastelloy C with corrosion-resistant alloy
braze.
Number of Flow Sensing Points per System: Up to 16 points
total.
Process Connection:
Standard: 2 inch male NPT or 3 inch 150 lb. raised
face stainless steel flange.
Optional: Other flange sizes and material types.
Insertion Length: Variable insertion lengths,
customer specified.
Operating Temperature:
Standard: -50° to +350° F [-45° to +177° C]
Optional: -50° to +850° F [-45° to +454° C]
Operating Pressure: To 50 psig [3.4 bar(g)]; design
pressure to 500 psig [34 bar(g)].
Optional Coatings: Electroless nickel, chromium
carbide, Hastelloy C.
Flow TransmitterOperating Temperature:
With LCD Display: -50° to +150° F [-45° to +66° C]
Without LCD Display: 0° to 140° F [-18° to 60° C]
Input Power:
Standard: 115 Vac (50/60 Hz), 50 watts maximum, 0.50
amp fuse.
Optional: 230 Vac (50/60 Hz), 50 watts maximum, 0.25
amp fuse, 100 Vac (50/60 Hz),
50 watts maximum, 0.50 amp fuse or 24 Vdc, 1.50 amp fuse..
Analog Output Signal:
Standard: 4 to 20 mA, 1000 Ω maximum load.
Optional: 10 to 50 mA, 400 Ω maximum load; 0 to 5 Vdc,
2 mA maximum current; 0 to 10 Vdc,
2 mA maximum current.
Conduit Connection: 1 inch female NPT.
Optional Remote Enclosure: Powder coated aluminum
enclosure is rated for NEMA/CSA Type 4 (equivalent to IP66).
An optional enclosure for hazardous locations is available.
Optional Interconnecting Cable: 10 ft. [7.6 m] PVC
cable (standard), custom lengths are available.
|
| |
|