Flow, level, and temperature instrument innovators since 1964
   

ST100 Series Mass Flow Meter Specifications

Instrument

Measuring Capability

ST1XX Models: Flow rate, total flow and temperature
STP1XX Models: Flow rate, total flow, temperature and pressure

Basic Style

ST100:Insertion, single-point
ST100L:In-line (spool piece), single-point
ST102:Insertion, dual-element system
ST110:Insertion, single-point with VeriCal™ capability
ST112:Insertion, dual-element system with VeriCal™ capability
STP100:Insertion, single-point with pressure measurement
STP102:Insertion, dual-element system with pressure measurement
STP110:Insertion, single-point with pressure measurement and VeriCal™ capability
STP112:Insertion, dual-element system with pressure measurement and VeriCal™ capability

Flow Measurement Range

Insertion Style:0.25 SFPS to 1000 SFPS [0,07 NMPS to 305 NMPS]
ST100L In-line:0.0062 SCFM to 1850 SCFM [0.01 Nm3/h to 3,140 Nm3/h]
– Air at standard conditions; 70 °F and 14.7 psia [0 °C and 1,01325 bar (a)]

Temperature Measurement Range

Up to 850 °F [454 °C] commensurate with element; see Operating
Temperature in Flow Element specification

Pressure Measurement Range (STP Models)

Available Ranges:
0 psig to 50 psig [0 bar (g) to 3,4 bar (g)]
0 psig to 160 psig [0 bar (g) to 11 bar (g)]
0 psig to 500 psig [0 bar (g) to 34 bar (g)
0 psig to 1000 psig 0 bar (g) to 70 bar (g)]
Media All gases that are compatible with the flow element material

Accuracy

Flow:
Gas Specific Calibration: ± 0.75% reading, ± 0.5% full scale
SpectraCal Gas Equivalency: Typically ± 4% reading, ± 0.5% full scale; gas conditions specific to application will determine accuracy; utilize FCI's online tool, AVAL, to evaluate your application and provide expected accuracy
Temperature: ± 2 °F [± 1.1 °C] (display only, flow rate must be greater than 5 AFPS [1,5 m/sec])
Pressure (STP Models): ± 1.0% of span

Temperature Coefficient

With optional temperature compensation; valid from 10% to 100% of full scale calibration
Flow:Maximum ± 0.015% of reading / °F up to 850 °F [± 0.03% of reading / °C up to 454 °C]

Repeatability

Flow: ± 0.5% reading
Temperature: ± 1 °F [± 1 °C] (flow rate must be greater than 5 AFPS [1,5 NMPS])
Pressure (STP Models): ≤ 0.1% of span

Turndown Ratio

Normally factory set and field adjustable from 2:1 to 100:1 within calibrated flow range; up to 1000:1 possible with factory evaluation of application

Temperature Compensation

Standard: ± 30 °F [± 16 °C]
Optional: ± 100 °F [± 55 °C]
Agency Approvals (Pending)
FM, FMc:

ATEX and IECEx:

CPA, NEPSI, Inmetro,
GOST-R, GOST-K

Ex-rated pressure transducer STP Models:
FM, CSA:

ATEX:
Class I, Division 1, Hazardous Locations;
Groups B,C,D,E,F,G
Zone 1, II 2 GD Ex d IIC T4 (pending)

(pending)



Class 1, Division 1, Groups A,B,C,D
Dust ignition proof for Class 1, Division 1, Groups E,F,G
2 G Ex d C T4, Ex d IIC T5, Ex d IIC T6
Calibration Performed on NIST traceable flow stands and equipment

Flow Element

Material of Construction All-welded 316L stainless steel.

Operating Pressure

Insertion Types
ST Models
Metal ferrule: 1000 psig [69 bar (g)]
Teflon ferrule: 150 psig [10 bar (g)] (200 °F [93 °C] maximum)
Fixed Connection NPT: 1000 psig [69 bar (g)]
Fixed Connection Flanged: per flange rating
STP Models: per above or pressure sensor rating, whichever is less
Inline Type (Model ST100L): 1000 psig [69 bar (g)]

Operating Temperature (Process)

ST100, ST102 Insertion Style
All Flow Elements (– FPC, – FP and – S):
-40 °F to 350 °F [-40 °C to 177 °C]
-40 °F to 500 °F [-40 °C to 260 °C]
-40 °F to 850 °F [-40 °C to 454 °C]
ST110, ST112 Insertion Style
– FP Style Flow Element:
-40 °F to 350 °F [-40 °C to 177 °C]
-40 °F to 500 °F [-40 °C to 260 °C]
STP Series Insertion Style
– FP Style Flow Element:
Standard Pressure Sensor: -32 °F to 176 °F [0 °C to 80 °C]
Ex-rated Pressure Sensor: -22 °F to 212 °F [-30 °C to 100 °C]
ST100L In-line Style
– FP and – S Style Flow Element:
-40 °F to 250 °F [-40 °C to 121 °C]

Process Connection

Compression Fittings Models ST100 and ST102 only
3/4" or 1" male NPT, stainless steel with adjustable Teflon ferrule or metal ferrule; or flanged tapped and threaded for 3/4" fitting, ANSI or DIN flanges
 
Compression fittings not available with 850 °F [454 °C] temperature versions of ST100 or ST102
 
Retractable Packing Glands
Low pressure 50 psig [3,5 bar (g)] or medium pressure 500 psig [34 bar (g)] with graphite or Teflon packing material; 1 1/4" male NPT or ANSI or DIN flange
 
Teflon packing required when process media is ozone, chlorine or bromine.
Remote configuration required with medium pressure packing gland.
 
Fixed Fittings / All Welded
1" male NPT or ANSI or DIN flange
 
Insertion Length
Field adjustable lengths:
1" to 6" [25 mm to 152 mm]
1" to 12" [25 mm to 305 mm]
1" to 21" [25 mm to 533 mm]
1" to 36" [25 mm to 914 mm]
1" to 60" [25 mm to 1524 mm]
Fixed lengths from 2.6" to 60" [66 mm to 1524 mm]
 

ST100L In-line Flow Tube

Flow element is threaded and keyed in an in-line flow tube, calibrated and supplied as a spool-piece; options include low flow injection tubes and built-in Vortab flow conditioners for optimum low flow rangeability and performance

Size: 1" diameter tubing; 1", 1 1/2" or 2" schedule 40 pipe
Length: 9 nominal diameters
Process Connections: Female NPT, male NPT, ANSI or DIN flanges, or butt weld prepared
Option: Flanges sized for flow tube

Remote Transmitter Configurations:

Transmitter may be mounted remotely from flow element using interconnecting cable (up to 1000' [300 m])

STP Models:

Additional Specifications on Pressure Sensor
 
Standard Sensor PSI Bar PSI Bar PSI Bar PSI Bar
Pressure range
Over pressure safety
Burst pressure
50
100
250
3,4
7
17,24
160
290
500
11
20
34
500
1000
2500
34
70
172
1000
1740
7975
70
120
550
Wetted Materials:
Connection
Pressure sensor

316L
PH 13-8 SS

316L
316L

316L
316L 

316L
316L
 
Ex Rated Sensor PSI Bar PSI Bar PSI Bar PSI Bar
Pressure range
Over pressure safety
Burst pressure
50
240
290
3,4
16,55
20
160
1160
1390
11
80
95,84
500
1160
5800
34
80
400
1000
1740
7970
70
120
549,5
Wetted Materials:
Connection
Pressure sensor

Stainless steel
Stainless steel

Stainless steel
Stainless steel

Stainless steel
SS and Elgiloy

Stainless steel
SS and Elgiloy

Flow Transmitter/Electronics

Operating Temperature

0 °F to 150 °F [-18 ° to 65 °C] (all except dual element models)
Dual-element Models: 0 °F to 130 °F [-18 ° to 54 °C]

Input Power

AC: 85 Vac to 265 Vac, 50 Hz to 60 Hz
DC: 24 Vdc ± 20%

Outputs

Analog
Standard: Three (3) 4-20 mA*, 0-1kHz, or 0-10 kHz pulse/frequency 4-20 mA outputs are user assignable to flow rate, temperature and/or if so equipped, pressure; outputs are user programmable to full flow range or subsets of full flow range; pulse/frequency output is user selectable as pulse for external counter/flow totalizer, or as 0-1 kHz or 0-10 kHz frequency representing flow rate

* Outputs are isolated and have fault indication per NAMUR NE43 guidelines, user selectable
for high (>21.0 mA) or low (<3.6 mA)


Optional: Standard output plus two (2) 2A SPDT relays Relays independently user assignable to flow, temperature or pressure; user programmable for hi/lo trip, hysteresis from 00.0 to 99.9 counts and time delay from 00.0 to 99.9 seconds

Digital
Standard:
Optional:


USB, Ethernet
HART (comes standard with analog outputs, V7 compliant)
Foundation fieldbus H1, PROFIBUS PA or Modbus RS-485
(* ST100 Series is cerified by and registred with the Fondation Fieldbus Organization)

Auxiliary Inputs

Two 4-20 mA input channels; used for FCI administered special configurations to allow ST100 Series to accept inputs from external devices such as gas analyzers, gas composition or pressure sensors

Enclosures

Main Transmitter / Electronics:
NEMA 4X, IP67; polyester powder coated aluminum; 4 conduit ports threaded as 1/2 " NPT or M20x1.5; 7.74 " x 5.40 " x 5.00 " [196.6 mm x 137.2 mm x 127 mm]; stainless steel enclosure pending

Local Enclosure (Remote Configuration):
Model ST100L, Models ST100 and ST102 without packing gland option:
NEMA 4X, IP67; polyester powder coated aluminum; 2 conduit ports threaded as 1/2 " NPT or M20x1.5; 3.75 " x 4.00 " x 3.24 " [95 mm x 102 mm x 82 mm]
Models ST100 and ST102 with medium pressure packing gland option; ST110, ST112 and all STP Models:
NEMA 4X, IP67; polyester powder coated aluminum; 1 conduit port threaded as 1 " NPT or M20x1.5;
5.40 " x 4.82 " [137.2 mm x 122 mm]

Data Logger

User programmable for readings per time increment to a maximum of 1 reading/second; removable, circuit board-mountable 2GB micro-SD (secure digital) memory card supplied; stores approximately 21M readings
in ASCII comma-separated format

Readout/Display and Optical Touch Buttons (Optional)

  • Large 2" x 2" [50 mm x 50 mm] LCD; digital plus bar graph and engineering units
  • Digital displays of flow rate, total flow, temperature and pressure (with STP models);
    user selectable for engineering units
  • Analog bar graph of flow rate
  • Relay/alarm status indication
  • User programmable 20 alphanumeric character field associated with each calibration group
  • Set-Up & Service mode displays text and service codes
  • Backlighted – backlight activated by proximity motion detection, or user may set for always on
  • Four (4) optical touch buttons for user programming of instrument set-up and service interrogation
  • Optical touch button activation through front window – no need to open enclosure to access or activate
  • Display is electronically rotatable in 90° increments to optimize viewing angle
Note: If readout/display not ordered, all user set-up and service interrogation must be done via computer
link to bus comm and/or USB port.

Other Options and Accessories

Vortab Flow Conditioners

Available for all line size applications; standard choice with Model ST100L (in-line)

Sun Shield, FCI part number 022378-01

Shades main transmitter electronics and display from direct sunlight. 316LSS

VeriCal Kit, FCI part number 020849-03

For use with VeriCal ready flow elements
(models ST110, ST112, STP110, STP112)
Portable test kit for controlling flow to elements, pressure regulation, digital pressure gauge and interconnection hose.

Ball Valves / Cable Glands

Element Coatings and Materials

For service in highly corrosive gases or with erosive particulates, FCI can provide special coatings and wetted materials to protect the element and provide longer service life; examples include Kynar, Tantalum, and chromium carbide

Certification and Testing Documentation

NACE, CMTR's, CRN registration, oxygen cleaning, welding qualifications, NIST certs, pressure testing, dye penetrant, and more available.


Specifications at reference operating conditions of 70 °F, 14.7 psia [21.1 °C, 1.013bar (a)] and straight pipe run 20d upstream, 10d downstream FCI is a continuous improvement company; specifications subject to change without notice


Home | About FCI | Products | Applications | Sales  | News/Events | Support | Contact FCI | Search | Site Map
©2012 Fluid Components International LLC. All Rights Reserved   Contact Us at 800-854-1993 or 760-744-6950
Legal & Privacy Statements