Mass Flow Meter Summary

The MT86 insertion type multipoint mass flow meter combines FCI's highly reliable thermal dispersion, no-moving parts flow element design with up to 16 flow sensing points while operating over a wide temperature range up to 850°F [454°C]. The electronics features continuous built-in testing and calibration adjustment to prevent signal drift. 

The MT86 multipoint mass flow meter is ideal for installation in air ducts, stacks, or wherever irregular flow profiles reduce the effectiveness of single-point metering.

Applications

  • Stack monitoring for CEMS
  • Primary air flow monitoring
  • Combustion air flow monitoring
  • Flue gas recirculation monitoring
  • Scrubber and precipitator balancing
  • Air monitoring to low NOX burners

Specifications

Flow Range: 0.25 SFPS to 150 SFPS [0,08 NMPS to 46 NMPS] in air at standard conditions of 70°F [21,1°C] and 14.7 psia [1,01325 bar (a)].

Accuracy: (at calibrated conditions) ± 2% of reading, ± 0.5% of full scale 

Temperature Coefficient:
With optional temperature compensation. Valid from 10% to 100% of full-scale calibration
Flow: Maximum ± 0.015% of reading/ºF up to 850ºF [±0.03% of reading/ºC up to 454ºC]

Repeatability: ± 1% reading

Turndown Ratio: From 5:1 to 100:1 within the calibrated flow range. 

Temperature Compensation: 
  • Standard: ± 30° F [± -1°C]
  • Optional: ± 100° F [± 38°C]

Enclosure: Powder coated aluminum enclosure is rated for NEMA/CSA Type 4 (equivalent to IP66). 
An optional enclosure for hazardous locations is available.

Agency Approvals: Contact FCI.

N.I.S.T. Certified Test Lab Calibration: Standard


Flow Element

Materials of Construction: 
  • Standard: 316 stainless steel with nickel braze per specification AMS 4777 for all wetted surfaces.
  • Optional: Hastelloy-C with corrosion-resistant alloy braze.
Number of Flow Sensing Points per System: Up to 16 points total

Process Connection: 
  • Standard: 2 inch MNPT or 3 inch 150 lb. raised face stainless steel flange
  • Optional: Other flange sizes and material types

Insertion Length: Variable insertion lengths, customer specified

Operating Temperature:
  • Standard: -50°F to 350°F [-45°C to 177°C]
  • Optional: -50°F to 850°F [-45°C to 454°C]

Operating Pressure: To 50 psig [3.4 bar(g)]; design pressure to 500 psig [34 bar(g)]

Optional Coatings: Electroless nickel, chromium carbide, Hastelloy-C


Flow Transmitter

Operating Temperature: 
  • With LCD Display: -50°F to +150°F [-45°C to 66°C]
  • Without LCD Display: 0°F to 140°F [-18°C to 60°C]

Input Power:
  • Standard: 115 Vac (50/60 Hz), 50 watts maximum, 0.50 amp fuse
  • Optional: 230 Vac (50/60 Hz), 50 watts maximum, 0.25 amp fuse, 100 Vac (50/60 Hz), 50 watts maximum, 0.50 amp fuse or 24 Vdc, 1.50 amp fuse

Analog Output Signal: 
  • Standard: 4-20 mA, 1000 Ω maximum load
  • Optional: 10-50 mA, 400 Ω maximum load; 0 Vdc to 5 Vdc, 2 mA maximum current; 0 Vdc to 10 Vdc, 2 mA maximum current

Conduit Connection: 1" female NPT

Optional Remote Enclosure: Powder coated aluminum enclosure is rated for NEMA/CSA Type 4 (equivalent to IP66); an optional enclosure for hazardous locations is available

Optional Interconnecting Cable: 10' [7,6 m] PVC cable (standard), custom lengths are available

Certification/Approvals

CECEMSEAC