FLT93B Flow Switch

Flow Switch for Set Point Accuracy with Variable Process Temperatures

The FLT93B BASIC insertion type FlexSwitch for flow and temperature monitoring represents the first true technological breakthrough in thermal technology in over a decade. FCI is the only thermal manufacturer providing temperature compensation to ensure set point accuracy for process temperatures that vary up to ±100°F. The FLT93B is easily field-configured, providing unparalleled flexibility, accuracy and stability for all multiple process sensing and switching requirements.

The FLT93B BASIC flow switch is available with all of the below listed standard features for a very attractive price and with quick delivery as soon as 2 business days ARO.
 

Applications

  • Pump protection
  • Cooling water/heat exchangers
  • Drain line flow
  • Safety spray nozzle monitoring
  • Oil well system testing
  • Relief valve monitoring

Specifications

For Flow Service - Setpoint Range:
  • Water-based Liquids:
0.01 to 3.0 fps [0.003 to 0.9 mps]
  • Hydrocarbon-based Liquids:
0.01 to 5.0 fps [0.003 to 1.5 mps]
  • Air/Gas:
0.25 to 120 sfps [0.08 to 37 smps] at standard conditions of 70° F [21.1° C] and 14.7 psia [1.013 bar(g)].

Accuracy: (whichever reading is higher)
  • Liquids: ± 0.5% reading or ± 0.04 fps [± 0.012 mps]
  • Gases: ± 0.5% reading or ± 2 sfps [± 0.06 nmps]
For Temperature Service:
Accuracy: ± 2° F [±1° C]
Repeatability: ± 1° F [± 0.6° C]

Response Time: As low as 3 seconds.

Enclosure: NEMA 4X/IP67 Rated. Standard: Polyester power coated aluminum, with 1" NPT conduit
port. Optional: Stainless steel. Optional: 2 conduit port, aluminum.

Compliances and Agency Approvals: FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro, EQM/ECAS. CE Marking. PED, CRN. (UKCA, UKEX pending)
Meets EC directives for EMC and LVD. Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
 
FM/FMc:
  XP, Class 1, Div. 1 Groups B,C,D, T3A or T4 Ta ≤60°C
EAC/TR CU
 
DIP, Class II/III, Div. 1, Groups E,F,G, T3A or T4 Ta ≤60°C
Nonincendive for Class I, II and III, Division 2, Groups A,B,C,D,E,F, and G, T3A or T4 -40°C ≤Ta≤60°C; hazardous (classified) locations, indoors and outdoors.
Type 4X
ATEX: Integral:                        II 2 G  Ex db IIC T4…T2 Gb
                                     II 2 D  Ex tb IIIC T135°C…T300°C Db
IECEx:
(EQM/ECAS)
Integral:                        Ex db IIC T4…T2 Gb
                                     Ex tb IIIC T135°C…T300°C Db                 
Optional N.I.S.T. Flow Calibration Services
Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
 

Flow Element

Materials of Construction: All welded 316L stainless steel for all wetted surfaces.

Process Connection: 0.75 inch male NPT

Insertion Length:
  • 1.2 inch [30 mm]
  • 2 inches [51 mm]
  • 4 inches [102 mm]

Operating Temperature: -40° to +350° F [-40° to +177° C]

Operating Pressure: To 3500 psig [240 bar(g)]
 

Control Circuit

Operating Temperature: -4° to +140° F [-20° to +60° C]

Universal AC/DC supply. Input terminals and jumpers on circut board select specific power.
 
AC 108-132V 13W, 100mA max.
AC 207-253V* 14W, 50mA max.
AC 18-28V 7W, 230mA max.
DC 21-30V 7W, 230mA max.
* AC mains preset by factory: FM & FMc as 108-132 Vac; All others as 207-240 Vac 

Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc.

Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.

Electrical Connection: 1 inch female NPT 

Certification/Approvals

ATEXCECRNFM ApprovedEACIECExSIL EQM-ECAS-logo.jpg